Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Appl Lab Med ; 9(2): 262-272, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38424720

RESUMO

BACKGROUND: Immunoassay measurements of serum alpha-gal (AG) specific IgE (sIgE) enable antibody detection and quantification with high sensitivity and specificity and are essential for AG syndrome diagnosis and patient management. We here present and analyze results from over 15 000 patient serum samples tested using the ImmunoCAP (Thermo/Phadia) assay. METHODS: AG-sIgE levels and positivity rates were correlated to patient age, gender, geographic location, repeat testing results, sIgE levels to co-tested red meat whole allergen extracts, and Rocky Mountain spotted fever (RMSF) serology performed on a subset of patient samples. RESULTS: Of the tested samples, 36.7% contained detectable (>0.1 KUA/L) AG-sIgE. Antibody levels were higher in patients of older age, in samples submitted from lower midwestern and southern states, and during the June-December period of the year. Specific IgE to co-tested red meat whole allergens showed moderate to strong correlation to AG-sIgE and were of lower levels. Samples with positive RMSF IgG titers (≥1:64) were of overall higher AG-IgE levels. CONCLUSION: Findings are consistent with the role of lone star ticks in AG syndrome pathogenesis. Levels of measured sIgE to AG are higher than co-tested sIgE to red meat whole allergen, consistent with the improved diagnostic performance of component-resolved testing.


Assuntos
Hipersensibilidade Alimentar , Humanos , Hipersensibilidade Alimentar/diagnóstico , Alérgenos , Imunoensaio/métodos , Imunoglobulina E
2.
Clin Biochem ; 117: 53-59, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35640680

RESUMO

We are entering the 5th decade of the HIV epidemic and although there is no cure, critical advances have been made in treatment, prevention and diagnostics, transforming HIV into a survivable disease. Due to these advances, the UNAIDS has set a goal of "90-90-90" target by 2020, which has been extended now to 2030, to have 90% of individuals infected with HIV diagnosed, 90% of those diagnosed linked to care and 90% of people receiving ART and 90% of those receiving ART achieving an undetectable viral load. Today, the focus is on U = U, "undetectable equals untransmittable", which takes advantage of improved diagnostics and treatment and preventive therapies that are combined with scale-up strategies. This article will review the advances in testing strategies and diagnostics, including rapid diagnostic tests and next generation sequencing, as well as the challenges that pre-exposure prophylaxis (PrEP) and post-exposure prophylaxis (PEP) now present for diagnosing and managing HIV infection.


Assuntos
Fármacos Anti-HIV , Infecções por HIV , Profilaxia Pré-Exposição , Humanos , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Carga Viral , Fármacos Anti-HIV/uso terapêutico
3.
PLoS One ; 17(7): e0271597, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35867681

RESUMO

OBJECTIVES: Emergency department (ED) health care personnel (HCP) are at risk of exposure to SARS-CoV-2. The objective of this study was to determine the attributable risk of SARS-CoV-2 infection from providing ED care, describe personal protective equipment use, and identify modifiable ED risk factors. We hypothesized that providing ED patient care increases the probability of acquiring SARS-CoV-2 infection. METHODS: We conducted a multicenter prospective cohort study of 1,673 ED physicians, advanced practice providers (APPs), nurses, and nonclinical staff at 20 U.S. centers over 20 weeks (May to December 2020; before vaccine availability) to detect a four-percentage point increased SARS-CoV-2 incidence among HCP related to direct patient care. Participants provided monthly nasal and serology specimens and weekly exposure and procedure information. We used multivariable regression and recursive partitioning to identify risk factors. RESULTS: Over 29,825 person-weeks, 75 participants (4.5%) acquired SARS-CoV-2 infection (31 were asymptomatic). Physicians/APPs (aOR 1.07; 95% CI 0.56-2.03) did not have higher risk of becoming infected compared to nonclinical staff, but nurses had a marginally increased risk (aOR 1.91; 95% CI 0.99-3.68). Over 99% of participants used CDC-recommended personal protective equipment (PPE), but PPE lapses occurred in 22.1% of person-weeks and 32.1% of SARS-CoV-2-infected patient intubations. The following factors were associated with infection: household SARS-CoV-2 exposure; hospital and community SARS-CoV-2 burden; community exposure; and mask non-use in public. SARS-CoV-2 intubation was not associated with infection (attributable risk fraction 13.8%; 95% CI -2.0-38.2%), and nor were PPE lapses. CONCLUSIONS: Among unvaccinated U.S. ED HCP during the height of the pandemic, the risk of SARS-CoV-2 infection was similar in nonclinical staff and HCP engaged in direct patient care. Many identified risk factors were related to community exposures.


Assuntos
COVID-19 , COVID-19/epidemiologia , Serviço Hospitalar de Emergência , Pessoal de Saúde , Humanos , Assistência ao Paciente , Estudos Prospectivos , SARS-CoV-2
4.
Clin Lab Med ; 42(1): 1-13, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35153044

RESUMO

In 2019, an emerging coronavirus, SARS-COV-2, was first identified. In the months since, SARS-CoV-2 has become a global pandemic of unimaginable scale. In 2021, SARS-CoV-2 continues to be a huge public health burden and a dominating issue in health care. In addition, SARS-CoV-2 has placed a spotlight on laboratory medicine and its key role in infectious disease management. The SARS-CoV-2 antibody testing landscape is vast and consists of dozens of antibody tests that have received EUA. The laboratory is faced with choosing the right test, staying current with the rapidly evolving recommendations, and updating test information for clients and clinicians. This review addresses what we know about the humoral response in SARS-CoV-2 infection and how this knowledge translates into appropriate serology test choice, utility, and interpretation.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Laboratórios , Pandemias
5.
Hum Gene Ther ; 33(7-8): 432-441, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35156839

RESUMO

Adeno-associated virus (AAV)-mediated gene therapy may provide durable protection from bleeding events and reduce treatment burden for people with hemophilia A (HA). However, pre-existing immunity against AAV may limit transduction efficiency and hence treatment success. Global data on the prevalence of AAV serotypes are limited. In this global, prospective, noninterventional study, we determined the prevalence of pre-existing immunity against AAV2, AAV5, AAV6, AAV8, and AAVrh10 among people ≥12 years of age with HA and residual FVIII levels ≤2 IU/dL. Antibodies against each serotype were detected using validated, electrochemiluminescent-based enzyme-linked immunosorbent assays. To evaluate changes in antibody titers over time, 20% of participants were retested at 3 and 6 months. In total, 546 participants with HA were enrolled at 19 sites in 9 countries. Mean (standard deviation) age at enrollment was 36.0 (14.87) years, including 12.5% younger than 18 years, and 20.0% 50 years of age and older. On day 1, global seroprevalence was 58.5% for AAV2, 34.8% for AAV5, 48.7% for AAV6, 45.6% for AAV8, and 46.0% for AAVrh10. Considerable geographic variability was observed in the prevalence of pre-existing antibodies against each serotype, but AAV5 consistently had the lowest seroprevalence across the countries studied. AAV5 seropositivity rates were 51.8% in South Africa (n = 56), 46.2% in Russia (n = 91), 40% in Italy (n = 20), 37.2% in France (n = 86), 26.8% in the United States (n = 71), 26.9% in Brazil (n = 26), 28.1% in Germany (n = 89), 29.8% in Japan (n = 84), and 5.9% in the United Kingdom (n = 17). For all serotypes, seropositivity tended to increase with age. Serostatus and antibody titer were generally stable over the 6-month sampling period. As clinical trials of AAV-mediated gene therapies progress, data on the natural prevalence of antibodies against various AAV serotypes may become increasingly important.


Assuntos
Dependovirus , Hemofilia A , Anticorpos Neutralizantes , Anticorpos Antivirais , Dependovirus/genética , Vetores Genéticos/genética , Hemofilia A/epidemiologia , Hemofilia A/genética , Hemofilia A/terapia , Humanos , Estudos Prospectivos , Estudos Soroepidemiológicos , Sorogrupo
6.
J Appl Lab Med ; 7(3): 698-710, 2022 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-34741514

RESUMO

BACKGROUND: Numerous serology assays are available for detection of SARS-CoV-2 antibodies but are limited in that only 1 or 2 target antigen(s) can be tested at a time. Here, we describe a novel multiplex assay that simultaneously detects and quantifies IgG antibodies to SARS-CoV-2 antigens, spike (S), nucleocapsid (N), receptor-binding domain (RBD), and N-terminal domain (NTD) in a single well. METHODS: Sensitivity was determined using samples (n = 124) from confirmed SARS-CoV-2 RT-PCR positive individuals. Prepandemic (n = 100) and non-COVID respiratory infection positive samples (n = 100) were used to evaluate specificity. Samples were analyzed using COVID-19 IgG multiplex serology assay from Meso Scale Discovery (MSD) and using commercial platforms from Abbott, EUROIMMUN, and Siemens. RESULTS: At >14 days post-PCR, MSD assay displayed >98.0% sensitivity [S 100% (95% CI 98.0%-100.0%); N 98.0% (95% CI 97.2%-98.9%); RBD 94.1% (95% CI 92.6%-95.6%); NTD 98.0% (95% CI, 97.2%-98.9%)] and 99% specificity (95% CI 99.3%-99.7%) for antibodies to all 4 antigens. Parallel assessment of antibodies to more than 1 antigen improved the sensitivity to 100% (95% CI 98.0%-100.0%) while maintaining 98% (95% CI 97.6%-98.4%) specificity regardless of the combinations used. When AU/mL concentrations of IgG antibodies from the MSD assay were compared against the corresponding IgG signals acquired from the single target commercial assays, the following correlations were observed: Abbott (vs MSD N, R2 = 0.73), Siemens (vs MSD RBD, R2 = 0.92), and EUROIMMUN (vs MSD S, R2 = 0.82). CONCLUSION: MSD assay offers an accurate and a comprehensive assessment of SARS-CoV-2 antibodies with higher sensitivity and equivalent specificity compared to the commercial IgG serology assays.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Teste Sorológico para COVID-19 , Humanos , Imunoglobulina G , Sensibilidade e Especificidade
7.
Sci Rep ; 11(1): 24507, 2021 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-34969960

RESUMO

Diagnostic tests that detect antibodies (AB) against SARS-CoV-2 for evaluation of seroprevalence and guidance of health care measures are important tools for managing the COVID-19 pandemic. Current tests have certain limitations with regard to turnaround time, costs and availability, particularly in point-of-care (POC) settings. We established a hemagglutination-based AB test that is based on bi-specific proteins which contain a dromedary-derived antibody (nanobody) binding red blood cells (RBD) and a SARS-CoV-2-derived antigen, such as the receptor-binding domain of the Spike protein (Spike-RBD). While the nanobody mediates swift binding to RBC, the antigen moiety directs instantaneous, visually apparent hemagglutination in the presence of SARS-CoV-2-specific AB generated in COVID-19 patients or vaccinated individuals. Method comparison studies with assays cleared by emergency use authorization demonstrate high specificity and sensitivity. To further increase objectivity of test interpretation, we developed an image analysis tool based on digital image acquisition (via a cell phone) and a machine learning algorithm based on defined sample-training and -validation datasets. Preliminary data, including a small clinical study, provides proof of principle for test performance in a POC setting. Together, the data support the interpretation that this AB test format, which we refer to as 'NanoSpot.ai', is suitable for POC testing, can be manufactured at very low costs and, based on its generic mode of action, can likely be adapted to a variety of other pathogens.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , Testes Diagnósticos de Rotina/métodos , Testes de Hemaglutinação/métodos , Testes Imediatos , Glicoproteína da Espícula de Coronavírus/imunologia , Humanos , Estudo de Prova de Conceito
8.
Emerg Infect Dis ; 27(11): 2786-2794, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34469285

RESUMO

We aimed to generate an unbiased estimate of the incidence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in 4 urban counties in Utah, USA. We used a multistage sampling design to randomly select community-representative participants >12 years of age. During May 4-June 30, 2020, we collected serum samples and survey responses from 8,108 persons belonging to 5,125 households. We used a qualitative chemiluminescent microparticle immunoassay to detect SARS-CoV-2 IgG in serum samples. We estimated the overall seroprevalence to be 0.8%. The estimated seroprevalence-to-case count ratio was 2.5, corresponding to a detection fraction of 40%. Only 0.2% of participants from whom we collected nasopharyngeal swab samples had SARS-CoV-2-positive reverse transcription PCR results. SARS-CoV-2 antibody prevalence during the study was low, and prevalence of PCR-positive cases was even lower. The comparatively high SARS-CoV-2 detection rate (40%) demonstrates the effectiveness of Utah's testing strategy and public health response.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Probabilidade , Estudos Soroepidemiológicos , Utah/epidemiologia
9.
Clin Chem ; 67(9): 1188-1200, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34470034

RESUMO

BACKGROUND: The clinical laboratory continues to play a critical role in managing the coronavirus pandemic. Numerous US Food and Drug Administration emergency use authorization (EUA) and laboratory-developed test (LDT) serologic assays have become available. The performance characteristics of these assays and their clinical utility continue to be defined in real time during this pandemic. The AACC convened a panel of experts from clinical chemistry, microbiology, and immunology laboratories; the in vitro diagnostics industry; and regulatory agencies to provide practical recommendations for implementation and interpretation of these serologic tests in clinical laboratories. CONTENT: The currently available EUA serologic tests and platforms, information on assay design, antibody classes including neutralizing antibodies, and the humoral immune responses to SARS-CoV-2 are discussed. Verification and validation of EUA and LDT assays are described, along with a quality management approach. Four indications for serologic testing are outlined. Recommendations for result interpretation, reporting comments, and the role of orthogonal testing are also presented. SUMMARY: This document aims to provide a comprehensive reference for laboratory professionals and healthcare workers to appropriately implement SARS-CoV-2 serologic assays in the clinical laboratory and to interpret test results during this pandemic. Given the more frequent occurrence of outbreaks associated with either vector-borne or respiratory pathogens, this document will be a useful resource in planning for similar scenarios in the future.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Laboratórios/normas , SARS-CoV-2/isolamento & purificação , Anticorpos Antivirais/biossíntese , Anticorpos Antivirais/imunologia , COVID-19/virologia , Humanos , SARS-CoV-2/imunologia
10.
Res Sq ; 2021 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-34312614

RESUMO

Diagnostic tests that detect antibodies (AB) against SARS-CoV-2 for evaluation of seroprevalence and guidance of health care measures are important tools for managing the COVID-19 pandemic. Current tests have certain limitations with regard to turnaround time, costs and availability, particularly in point-of-care (POC) settings. We established a hemagglutination-based AB test (HAT) that is based on bi-specific proteins which contain a dromedary-derived antibody (nanobody) binding red blood cells (RBD) and a SARS-CoV-2-derived antigen, such as the receptor-binding domain of the Spike protein (Spike-RBD). While the nanobody mediates swift binding to RBC, the antigen moiety directs instantaneous, visually apparent hemagglutination in the presence of SARS-CoV-2-specific AB generated in COVID-19 patients or vaccinated individuals. Method comparison studies with assays cleared by emergency use authorization (EUA) demonstrate high specificity and sensitivity. To further increase objectivity of test interpretation, we developed an image analysis tool based on digital image acquisition (via a cell phone) and a machine learning algorithm based on defined sample-training and -validation datasets. Preliminary data, including a small clinical study, provides proof of principle for test performance in a POC setting. Together, the data support the interpretation that this AB test format, which we refer to as 'NanoSpot.ai', is suitable for POC testing, can be manufactured at very low costs and, based on its generic mode of action, can likely be adapted to a variety of other pathogens.

11.
Arch Pathol Lab Med ; 145(10): 1212-1220, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34181714

RESUMO

CONTEXT.­: Emerging evidence shows correlation between the presence of neutralization antibodies (nAbs) and protective immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently available commercial serology assays lack the ability to specifically identify nAbs. An enzyme-linked immunosorbent assay-based nAb assay (GenScript cPass neutralization antibody assay) has recently received emergency use authorization from the Food and Drug Administration. OBJECTIVE.­: To evaluate the performance characteristics of this assay and compare and correlate it with the commercial assays that detect SARS-CoV-2-specific immunoglobulin G (IgG). DESIGN.­: Specimens from SARS-COV-2 infected patients (n = 124), healthy donors obtained prepandemic (n = 100), and patients with non-coronavirus disease 2019 (COVID-19) respiratory infections (n = 92) were analyzed using this assay. Samples with residual volume were also tested on 3 commercial serology platforms (Abbott, Euroimmun, Siemens). Twenty-eight randomly selected specimens from patients with COVID-19 and 10 healthy controls were subjected to a plaque reduction neutralization test. RESULTS.­: The cPass assay exhibited 96.1% (95% CI, 94.9%-97.3%) sensitivity (at >14 days post-positive PCR), 100% (95% CI, 98.0%-100.0%) specificity, and zero cross-reactivity for the presence of non-COVID-19 respiratory infections. When compared with the plaque reduction assay, 97.4% (95% CI, 96.2%-98.5%) qualitative agreement and a positive correlation (R2 = 0.76) was observed. Comparison of IgG signals from each of the commercial assays with the nAb results from plaque reduction neutralization test/cPass assays displayed greater than 94.7% qualitative agreement and correlations with R2 = 0.43/0.68 (Abbott), R2 = 0.57/0.85 (Euroimmun), and R2 = 0.39/0.63 (Siemens), respectively. CONCLUSIONS.­: The combined data support the use of cPass assay for accurate detection of the nAb response. Positive IgG results from commercial assays associated reasonably with nAbs presence and can serve as a substitute.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina G/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/epidemiologia , COVID-19/virologia , Criança , Pré-Escolar , Estudos de Coortes , Epidemias/prevenção & controle , Humanos , Imunoglobulina G/sangue , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , SARS-CoV-2/genética , SARS-CoV-2/fisiologia , Sensibilidade e Especificidade , Adulto Jovem
12.
Virol J ; 18(1): 1, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33397387

RESUMO

BACKGROUND: Virus neutralization by antibodies is an important prognostic factor in many viral diseases. To easily and rapidly measure titers of neutralizing antibodies in serum or plasma, we developed pseudovirion particles composed of the spike glycoprotein of SARS-CoV-2 incorporated onto murine leukemia virus capsids and a modified minimal murine leukemia virus genome encoding firefly luciferase. This assay design is intended for use in laboratories with biocontainment level 2 and therefore circumvents the need for the biocontainment level 3 that would be required for replication-competent SARS-CoV-2 virus. To validate the pseudovirion assay, we set up comparisons with other available antibody tests including those from Abbott, Euroimmun and Siemens, using archived, known samples. RESULTS: 11 out of 12 SARS-CoV-2-infected patient serum samples showed neutralizing activity against SARS-CoV-2-spike pseudotyped MLV viruses, with neutralizing titers-50 (NT50) that ranged from 1:25 to 1:1,417. Five historical samples from patients hospitalized for severe influenza infection in 2016 tested negative in the neutralization assay (NT50 < 25). Three serum samples with high neutralizing activity against SARS-CoV-2/MLV pseudoviruses showed no detectable neutralizing activity (NT50 < 25) against SARS-CoV-1/MLV pseudovirions. We also compared the semiquantitative Siemens SARS-CoV-2 IgG test, which measures binding of IgG to recombinantly expressed receptor binding domain of SARS-CoV-2 spike glycoprotein with the neutralization titers obtained in the pseudovirion assay and the results show high concordance between the two tests (R2 = 0.9344). CONCLUSIONS: SARS-CoV-2 spike/MLV pseudovirions provide a practical means of assessing neutralizing activity of antibodies in serum or plasma from infected patients under laboratory conditions consistent with biocontainment level 2. This assay offers promise also in evaluating immunogenicity of spike glycoprotein-based candidate vaccines in the near future.


Assuntos
COVID-19/imunologia , Leucemia/imunologia , Testes de Neutralização/métodos , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Vírion/imunologia , Enzima de Conversão de Angiotensina 2/imunologia , Animais , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Células HEK293 , Humanos , Imunoglobulina G/sangue , Camundongos
13.
J Appl Lab Med ; 6(3): 614-624, 2021 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-33064790

RESUMO

BACKGROUND: As serologic assays for SARS-CoV-2 become more widely utilized, it is important to understand their performance characteristics and correlation with neutralizing antibodies. We evaluated 3 commonly used SARS-CoV-2 IgG assays (Abbott, DiaSorin, and EUROIMMUN) for clinical sensitivity, specificity, and correlation with neutralizing antibodies, and then compared antibody kinetics during the acute phase of infection. METHODS: Three panels of samples were tested on every assay. Sensitivity was assessed using a panel of 35 specimens serially collected from 7 patients with RT-PCR-confirmed COVID-19. Specificity was determined using 100 sera samples collected in 2018 from healthy individuals prior to the outbreak. Analytical specificity was determined using a panel of 37 samples from individuals with respiratory illnesses other than COVID-19. RESULTS: Clinical sensitivity was 91.43% (95% CI 76.94-98.20%) for Abbott, and 88.57% (95% CI 73.26-96.80%) for both DiaSorin and EUROIMMUN. Clinical specificity was 99.00% (95% CI 94.55-99.97%) for Abbott and DiaSorin and 94.00% (95% CI 87.40-97.77%) for EUROIMMUN. The IgG assays demonstrated good qualitative agreement (minimum of 94%) and good correlation between the quantitative result for each combination of assays (r2 ≥ 0.90). The neutralizing antibody response did not necessarily follow the same temporal kinetics as the IgG response and did not necessarily correlate with IgG values. CONCLUSION: The 3 IgG antibody assays demonstrated comparable performance characteristics. Importantly, a qualitative positive IgG result obtained with any of the assays was associated with the presence of neutralizing antibodies; however, neutralizing antibody concentrations did not correlate well with signal to cutoff ratios.


Assuntos
Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/imunologia , Imunoglobulina G/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Teste Sorológico para COVID-19/métodos , Criança , Pré-Escolar , Ensaio de Imunoadsorção Enzimática , Feminino , Ensaios de Triagem em Larga Escala , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
15.
bioRxiv ; 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-32995778

RESUMO

Antibody neutralization is an important prognostic factor in many viral diseases. To easily and rapidly measure titers of neutralizing antibodies in serum or plasma, we developed pseudovirion particles composed of the spike glycoprotein of SARS-CoV-2 incorporated onto murine leukemia virus capsids and a modified minimal MLV genome encoding firefly luciferase. These pseudovirions provide a practical means of assessing immune responses under laboratory conditions consistent with biocontainment level 2.

16.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-32350047

RESUMO

The emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) brought with it rapid development of both molecular and serologic assays for identification of COVID-19 infections. While Food and Drug Administration (FDA) emergency use authorization (EUA) is required for clinical application of SARS-CoV-2 molecular tests, submission for EUA is currently a voluntary process for manufacturers of serologic assays. The absence of FDA oversight of serologic tests is concerning given that the commercially available serologic assays are highly variable, differing in their format, the antibody class detected, the targeted antigen, and the acceptable specimen types. An added complication is the lack of a clear understanding for how such assays should be utilized and what the reported results ultimately indicate or, perhaps more importantly, what they do not indicate. Here, we provide a brief summary of the performance of a number of serologic assays reported in the literature, comment on what we do and do not know regarding our immune response to SARS-CoV-2, and provide a number of scenarios for which serologic testing will play a role during our global response to this pandemic.


Assuntos
Anticorpos Antivirais/sangue , Betacoronavirus/imunologia , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/normas , Humanos , Pandemias , SARS-CoV-2
17.
Sex Transm Dis ; 47(5S Suppl 1): S13-S17, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32343517

RESUMO

BACKGROUND: Geenius HIV 1/2 Supplemental Assay (Geenius; Bio-Rad Laboratories) is the only Food and Drug Administration-approved HIV-1/HIV-2 antibody differentiation test for the second step in the HIV laboratory testing algorithm. We characterized the occurrence of true HIV-1 and HIV-2 infections as well as false results in 6 US clinical laboratories using Geenius. METHODS: We examined routine HIV testing outcome data from the time the laboratories began using the algorithm with Geenius until September 30, 2017. We calculated the positive predictive value for Geenius HIV-1 and HIV-2 reactivity separately. RESULTS: Of 5,046,684 specimens tested, 41,791 had reactive antigen/antibody test results. Most specimens with reactive antigen/antibody results were HIV-1 antibody-positive established infections (n = 32,421), 1,865 of which also had indeterminate HIV-2 bands present. Ninety-three specimens were HIV-2 antibody positive or untypable for HIV-1/HIV-2 antibody. Acute HIV-1 infections were found in 528 specimens; 881 specimens lacked the nucleic acid test to determine the possibility of acute HIV-1 infection. False-positive antigen/antibody test results were present in 7505 specimens. Few specimens (n = 363) had false-positive antigen/antibody results with indeterminate Geenius and negative HIV-1 nucleic acid test results. The positive predictive values of Geenius reactivity were 99.4% for HIV-1 and 4.3% for HIV-2. CONCLUSIONS: Routine testing using the laboratory testing algorithm with Geenius resulted in most specimens resolving as HIV negative or HIV-1 positive. The occurrence of indeterminate HIV-2 bands with a Geenius final assay interpretation of HIV-1 positive was more common than true HIV-2 infections. Reporting indeterminate HIV-2 results in this situation may cause confusion with interpreting HIV infection status.


Assuntos
Anticorpos Anti-HIV/sangue , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , HIV-1/imunologia , HIV-2/imunologia , Laboratórios/normas , Algoritmos , Infecções por HIV/virologia , Teste de HIV , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Humanos , Imunoensaio/métodos , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Testes Sorológicos/métodos
18.
Clin Chem ; 66(1): 229-238, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31672859

RESUMO

BACKGROUND: T-cell receptor excision circles (TREC) and κ-deleting recombination receptor excision circles (KREC) concentrations can be used to assess and diagnose immune deficiencies, monitor thymic and bone marrow immune reconstitution, or follow responses to drug therapy. We developed an assay to quantify TREC, KREC, and a reference gene in a single reaction using droplet digital PCR (ddPCR). METHODS: PCR was optimized for 3 targets: TREC, KREC, and ribonuclease P/MRP subunit p30 (RPP30) as the reference gene. Multiplexing was accomplished by varying the target's fluorophore and concentration. Correlation with clinical results was evaluated using 47 samples from healthy donors, 59 samples with T-cell and B-cell markers within the reference interval from the flow cytometry laboratory, 20 cord blood samples, and 34 samples submitted for exome sequencing for severe combined immunodeficiency disease (SCID). RESULTS: The limit of the blank was 4 positive droplets, limit of detection 9 positive droplets, and limit of quantification 25 positive droplets, or 2.0 copies/µL. TREC and KREC copies/µL were as expected in the healthy donors and cord blood samples and concordant with the healthy flow cytometry results. Of the samples from the SCID Panel, 56.5% had a TREC count <20 copies/µL and 17.7% had a KREC count <20 copies/µL, suggestive of low T- and B-cell numbers, respectively. CONCLUSIONS: Our multiplex ddPCR assay is an analytically sensitive and specific method for the absolute quantification of TREC and KREC. To the best of our knowledge, this paper is the first to describe the simultaneous quantification of TREC, KREC, and a reference gene by use of ddPCR.


Assuntos
Reação em Cadeia da Polimerase em Tempo Real/métodos , Receptores de Antígenos de Linfócitos T/genética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Linfócitos B/citologia , Linfócitos B/metabolismo , Criança , Pré-Escolar , Sangue Fetal/metabolismo , Humanos , Lactente , Recém-Nascido , Limite de Detecção , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase em Tempo Real/normas , Receptores de Antígenos de Linfócitos T/metabolismo , Recombinação Genética , Padrões de Referência , Imunodeficiência Combinada Severa/diagnóstico , Imunodeficiência Combinada Severa/genética , Linfócitos T/citologia , Linfócitos T/metabolismo , Adulto Jovem
19.
Cytometry B Clin Cytom ; 96(4): 266-274, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31173473

RESUMO

BACKGROUND: Mass cytometry can differentiate more channels than conventional flow cytometry. However, for clinical use, standardization and agreement with well-established methods is paramount. We compared mass cytometry to standard clinical flow cytometry. METHODS: Mass and flow cytometry were performed in parallel on peripheral blood samples from 25 healthy individuals. Antibody staining was performed on the same samples at the same time, and analyzed for granulocyte, monocyte, lymphocyte, T, B, NK, CD4 and CD8 percentages. Validation parameters included comparison to flow cytometry, inter- and intra-assay precision and establishment of reference intervals. RESULTS: There was a positive correlation between mass and flow cytometry for the eight populations studied (R2 between 0.26 and 0.97). Slopes of the best-fit lines varied from 0.50 to 1.21 (fluorescence/mass). No significant differences in variance were found (F-test, P > 0.05). However, paired t-tests were significantly different for four of the eight markers (granulocytes, NK cells, T cells and CD4 cells), resulting in different reference intervals. Signal intensities were correlated for monocytes, lymphocytes, T, CD4 and CD8 cells (R2 = 0.41-0.57). The mass cytometry intra-assay precisions were 0.7-8.5% and inter-assay precisions 1.5-13.8%. CONCLUSION: Mass and flow cytometry evaluations of whole blood for major cell populations correlate with similar precision and signal intensity. However, for clinical use, separate reference interval studies are required. Cell population identification should rely on gating strategies that take advantage of the characteristics offered by each method. © 2019 International Clinical Cytometry Society.


Assuntos
Técnicas de Laboratório Clínico , Citometria de Fluxo , Adolescente , Adulto , Criança , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...